AndSolar rapid shutdown device
AMCL Gen2
Models sold
- AMCL-E2 (long cable)
20 A · Cuts DC on the roof in a fire or for maintenance
Works with most mainstream inverters (maker); the team checks the inverter and panels before installation
- Panels
- 1 device per 2 panels (or 1)
- Max input current
- 20 A
- Max system voltage
- 1,500 V
- Shutdown
- < 30 V in 30 s
- IP rating
- IP68, under the panels outdoors
- Warranty
- Ask on LINE
Full specs
- Module-level shutdown to NEC 690.12, so technicians and firefighters can work on the roof safely
- Per-panel data in the app, to find a faulty panel quickly
- Needs the ADCU-M0 gateway (it sends the shutdown signal and the data to the app)
- Input voltage
- 8–80 V (single) · 8–120 V (dual)
- Max input current
- 20 A (short-circuit 30 A)
- Output
- 8–120 V · 20 A
- Max system voltage
- 1,500 V (the manual lists 600 / 1,000 / 1,500 V versions)
- Voltage when off
- Up to 1 V per device
- Shutdown
- Brings the panel strings below 30 V within 30 s
- How it shuts down
- Emergency switch · app/web · automatic on overheating (warning 75 °C, off at 85 °C)
- Panels
- 1 device per 2 panels (maker's advice) or 1 per panel
- Cables
- In 0.7 m(+) / 1.5 m(-) · out 0.3 m(+) / 2.7 m(-) (custom lengths)
- Connector
- MC4
- Per-panel data
- Voltage, current, power, temperature
- Communication
- Power-line comms (HPLC) to the ADCU gateway, up to 800 m · web and AndCloud app
- Ingress protection
- IP68 / Type 6P
- Flame rating
- UL94 5VA
- Operating temperature
- -40 to 85 °C
- Size
- 103 × 23 × 105 mm
- Installation
- Clips to the panel frame or rail, at least 15 mm off the roof
- Standards listed
- NEC 2017/2020/2023 (690.12), UL1741, UL3741, CSA C22.2 No.330, IEC/EN 62109-1, FCC Part 15, IEC/EN 61000-6, RoHS, REACH